CN

PLANAR HIGH CURRENT POWER INDUCTOR

PER33

Flat wire windings provide extremely low DC and AC resistance.

Low radiation noise by magnetically shielded construction

High temperature ferrite core

Operating temperature : -40℃~+125℃.

Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C / 85% relative humidity)

Contact Us

Specification

Reading

Application

Energy storage chokes for

Buck/boost choke for 48 V boardnet converter.

Filter for audio applications.

DC-DC converters.

Part number

料号

Inductance

电感量

μH±10%

DCR

最大直流电阻

Isat

直流饱和电流

A

Irms

温升电流

A

SRF

自谐频率

MHz

Length

mm

Width

mm

Height

mm

PER33-102KE10.85222723933.0±1.029.3±1.015.0±0.4
PER33-222KE2.21.2141592333.0±1.029.3±1.015.0±0.4
PER33-322KE3.20.8595721833.0±1.029.3±1.015.0±0.4
PER33-352KE3.51.281591733.0±1.029.3±1.015.0±0.4
PER33-472KE4.71.277591633.0±1.029.3±1.015.0±0.4
PER33-502KE51.273591533.0±1.029.3±1.015.0±0.4
PER33-562KE5.61.259591433.0±1.029.3±1.015.0±0.4
PER33-602KE61.2585912.533.0±1.029.3±1.015.0±0.4
PER33-682KE6.81.251591233.0±1.029.3±1.015.0±0.4
PER33-822KE8.21.239591033.0±1.029.3±1.015.0±0.4
PER33-103KE101.23259933.0±1.029.3±1.015.0±0.4
Standard products are stocked手指斜点.pngBuy in stock in small quantities

Remark:

① Inductance is measured with a LCR meter Agilent 4284A or equivalent.Test frequency at 100kHz

② DC resistance is measured with keithley 580 Milliohm Meter , or equivalent. Reference ambient temperature 25°C

③ SRF measured using an Agilent 4395A network analyzer and an Agilent 16193A test fixture.

④ DC current at 25°C that causes the specified Inductance drop from its value without current.

⑤ Current that causes the specified temperature rise from 25°C ambient. This information is for reference only and 

does not represent absolute maximum ratings.

⑥ Electrical specifications at 25°C


remark

Dimensions
规格尺寸-PER33
Electrical Characteristic Curve
曲线图-PER33


For reference only and does not represent the absolute maximum rating.